Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential

Product Details
Customization: Available
Type: Ultrasonic Flowmeter
Structure Type: Wall-Mounted
Manufacturer/Factory, Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Customization from Samples
The supplier provides sample based customization services
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (22)
  • Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
  • Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
  • Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
  • Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
  • Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
  • Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
Find Similar Products
  • Overview
  • Product Parameters
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
FMU832
Measuring Medium
Liquid
Output Signal Type
RS485 or 4-20mA
Production Process
Integration
Material
Plastic and Metal
Accuracy Grade
1.0G
IP Rating
IP68
Certification
CE
Customized
Customized
Product Name
Ultrasonic Flowmeter
Repeatability
0.2%
Range
0~ 5m/S
Measurement Period
500ms
Accuracy
1%Fs,-1%Fs
Power Supply
AC220V or DC24V
Pipe Size
15-6000mm
Output Signal
4~ 20mA, RS485, Modbus Protocol or Custom Protocol
Keywords
Clamp on Ultrasonic Flowmeter
Transport Package
Carton
Specification
2.75KG 28*24*19CM
Trademark
SENTEC
Origin
China
HS Code
9026100000
Production Capacity
50000

Product Description

FMU832 Ultrasonic flow meters are instruments that measure flow by detecting the effect of fluid flow on an ultrasonic beam (or ultrasonic pulse).
Clamp-on or tube-segment ultrasonic flow meters are based on the principle of "velocity difference method" to measure the liquid flow in a circular tube. It adopts advanced multi-pulse technology, signal digital processing technology and error correction technology, which makes the flow meter more suitable for the environment of the industrial site, and the measurement is more convenient, economical and accurate. The products have reached the advanced level at home and abroad, and can be widely used in petroleum, chemical, metallurgy, electric power, water supply and drainage and other fields.

Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output ResidentialInsertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
Product Parameters
Products name Ultrasonic flow meter/heat meter
Main unit Accuracy Better than ±1%
Repeatability Better than 0.2%
Principle Transit-time measuring principle
Measurement Period 500ms
Display LCD with backlight, display accumulated flow/heat, instantaneous flow/heat, velocity, time etc.
Output Analogue output: 4-20mA or 0-20mA current output. Impedance 0∼1kW. Accuracy 0.1%.
OCT output: Frequency signal (1~9999HZ)
Relay output: over 20 source signal (no signal, reverse flow etc.)
RS485 serial port
  Input Three analogue input
Three-wire PT100 resistor input (optional)
Other functions Automatically record the totaliser data of the last 64 days / 64 months / 5 years;

 

The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation

The instrument working status of the last 64 days

pipe material Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed
Size 15-6000mm
Straight pipe section In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter)
Liquid Types Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid
Temperature Standard: -30C - 90C ,High-temperature:-30C - 160C
Turbidity Less than 10000ppm, with a little bubble
  Flow Direction Bi-directional measuring, net flow/heat measuring
Environment Temperature Main Unit: -30C - 80C
Transducer: -40C -110C, Temperature transducer: select on enquiry
Humidity Main Unit: 85% RH
Transducer: water-immersible, water depth less than 3m
Cable Twisted Pair Line, standard length of 20m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement.

 

RS-485 interface, transmission distance up to 1000m

Power Supply AC220V or DC24V
Power Consumption Less than 1.5W
Protocols MODBUS, M-BUS, Fuji extended protocol and other factory protocol
Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output ResidentialInsertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output ResidentialInsertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output ResidentialInsertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output ResidentialInsertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output ResidentialInsertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output ResidentialInsertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
Company Profile

SENTEC concentrates on the solutions for sensing technology.

For decades, SENTEC quality guaranteed products insist strictly manufactured in accordance with ISO, CE directive and fully RoHS compliant. On the basis of large-scaled production factories and international excellent devices, SENTEC inspections, tests and calibrations are well recognized throughout the world with experienced OEM service.
The advance solutions, superior quality, reliable performance, customer satisfaction and excel-
lent technical services are always our sole and eternal goal !Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential


Insertion Clamp on Type Ultrasonic Flowmeter Optical Flow Sensor Modbus Output Residential
FAQ

1. Could I have prices of your products?
Welcome. Pls feel free to send us an email here. You will get our reply in 24 hours

2. Can we print our logo/website/company name on products?
Yes, please advise the size and Pantone Code of the logo.

3. What's the lead time for regular order?
3~7 days for order quantity lower than 500pcs, For more quantity, usually 15 days.

4. Can I get a discount?
Yes, for the order quantity more than 50pcs, please contact us to get the best price.

5. What is your MOQ?
The MOQ of most of our products is 1PCS. You can also contact us to get a lower low MOQ.

6. How to contact you?

 

The specific price is subject to the parameters, please contact us for the quotation,the consultation is free of charge.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier